Wind Tower Foundations Built Firm and Fast

Photobucket

 WALKERTON, ONT.-BASED concrete contractor MAHCRETE has been building wind tower foundations since 2005, hut its largest project to date Canadian Hvdro’s \Xolf Island Wind Farm in Kingston, Ont. The ‘Xolf Island facility consists of 86 wind towers, each 285 ft from base to huh and each supporting 12 1-ft-long blades. MATTCRETE built the foundations for all 86 towers in only seven months (from September 2008 to March 2009), therefore efficiency and coordinated efforts were critical to the $480-million project’s success.
Each foundation used about 664 cuyds of concrete with a design compressive strength of just over 5000 psi. The mix design included a high slag content that helped control the heat generated by cement hydration and reduce cracking of the massive concrete slabs. But early strength development was important to keep the project on schedule. MA! ICRETE president 1att Jagelewski says, We needed to reach 4061 psi by 21 days to enable folks to set the towers on time.”
The typical foundation is octagonal, about 56 ft across, 6 ft 8 in. thick, and resting on bedrock. Two of the towers were located in areas with sandy soil; their foundations were each
supported by 24 caissons drilled to bedrock. A l7-ft-diarneter concrete cylinder extends about 6 ft above from the center of the octagon, containing anchor bolts to which the tower structure is attached. MATTCRETE designed and fabricated its own steel forms for the foundations, using one
piece of formwork for each side of the octagon. The forms were lifted into place using a crane, then bolted together to create the desired angles and tied back with telescoping adjustable braces.
Once the formwork was in place, MATTCRETE supervised a subcontractor’s installation of steel reinforcement before placing the concrete using two boom pumps.
Properly consolidating the concrete was an important step, ensuring that the foundations were strong and stable enough to support the towers. “You can’t vibrate it too much or the stone sinks,” Jagelewski says, “hut you have to get it around all the rebar and anchor bolts
without leaving voids.”
NIATTCRETE used a variety of vibrating equipment manufactured by Oztec Industries, Port Washington, N.Y., to keep the project moving. Three were Oztec Model GV-SW wheelbarrow units with 5-hp Honda gasoline engines, and another four were Model BP-5O, the vibrator manufacturer’s largest backpack vibrators, with 2 ½ -hp Honda engines. Both of these Oztec per units feature the company’s “speed-up” transmission, which maintains a vibration rate of 10,000 to 12,000 vpm, and both will run for an hour or more on a full tank of gas. With each of these vibrators, crews used 16-ft flexible shafts with 2½ -in.-diameter steel heads. MATTCRETE also kept about a dozen 214 -lip electric vibrators on hand for backup.
Jagelewski says everyone involved with the project was pleased with the efficiency of construction. “There’s a long lead time needed to get the wind towers and turbines—they have to he ordered about a year in advance—so Canadian Hydro was anxious to get them installed as soon as they were available. But everybody was amazed that we could place more than
73,000 cu yds of concrete in less than eight months.”
Photobucket

Vibration techniques

Vibrators are easy to operate, although getting good consolidation requires a knowledgeable craftsman. Some European countries actually require vibrator operators to he licensed. Here are few tips to improve consolidation:
• Do not use vibrators to move Concrete horizontally—this can result in separation of the aggregate from the paste (segregation). Vibrators can, however, he used to “melt” a pile of concrete that was placed by bucket or buggy.
• Keep lifts in walls and columns less than 20 inches thick or about the same as the length of the vibrator head.
• The critical questions for the vibrator operator are how far apart to insert the vibrator and how deep to penetrate into the preceding lift.
• Vibrators should he sized and positioned to ensure that all concrete within the forms falls within the radius of influence (see Fig. 1). Use the largest vibrator that will fit between the reinforcement. The center-to- center distance between vibrator insertions should be 1 ½ times the radius of influence of the vibrator.
• Lifts should he placed while the preceding lift is still soft enough to penetrated by the vibrator. If that’s impossible, vibrate near the cold joint hut realize that a lift line will be visible.
• A graphical technique can help to determine how deep to penetrate into the preceding lift. Knowing that the vibration waves slope up at about a 30 degree angle from the tip, place a 30-60-90 triangle at the midpoint between  the insertion points and measure the depth of revibration into the preceding lift and then the total insertion depth (see Fig. 2). Making sure that the boundary between lifts is vibrated will knit together the lifts and eliminate lift lines in the concrete.
• Insert the vibrator as quickly as possible to the proper depth into the previous lift. Typically it will sink under its own weight.
• Hold the vibrator at its maximum depth for S to 1S seconds. Withdraw it at 3 in./second for structural concrete or 2 in./second for architectural concrete (these are the withdrawal rates recommended by AC! 309). Slow withdrawal allows the vibrator to stay below the escaping air forcing it up and out of the concrete.
• Moving the vibrator up and down slightly closes the hole behind the vibrator.
• Make sure the vibrator head remains vertical—don’t force it in at an angle.
• Don’t force the vibrator into congested reinforced concrete because you can end up with a vibrator that is stuck in the reinforcement.
• Proper consolidation is often a judgment call—experienced operators can tell if they are getting good consolidation by the sound of the vibrator.
• Despite all this, if you still have hug holes in the concrete surfaces (after stripping the forms), reduce the distance between insertion points by 20% to 30% below the
standard 1½ times the radius of influence. If there are still some hug holes try spading near form surfaces
• Do not let the vibrator tip contact the form surfaces—this can damage the form panels. Rubber vibrator head tips can help reduce this potential damage.
• After the concrete surface has
stopped bleeding, revibration can he used to remove air pockets in the top lift. Don’t revibrate deeper than about 3 feet and also not with very stiff or harsh mixes.

• For exposed architectural concrete, experiment with vibration techniques to avoid color variations on the surface. For more information, read Guide to Cast-in-Place Architectural Concrete Practice, ACI 303 R-04. 
Photobucket 
FIGURE 1 Use the proper size of vibrator and keep vibrator insertions
at 1 ½ time the radius of influence

Photobucket 
FIGURE 2 A graphical technique can help in determining howdeep the vibrator shoul penetrate into the preceding lift.

lunes, 25 de octubre de 2010

Vibrating Self-Consolidating Concrete

By definition, self-consolidating concrete does not require mechanical consolidation. But the problems with SCC are that it is susceptible to segregation, requires more expertise and quality control, can be expensive, and is not always robust (meaning small changes in water content can cause big changes in workability). Even with true SCC (slump flow greater than 18 inches), contractors will sometimes use a little vibration just to make sure the mix is consolidated, especially with congested reinforcing steel. In a properly proportioned mix, this vibration will not lead to separation of the aggregate from the paste (segregation) although there can be some grout leakage at form joints. ‘With slump flows below about 23 inches,” said SCC researcher David Lange, professor at the University of Illinois Champaign, “there may be the need to vibrate just a little bit to help the material move, usually just at the end of the pour when finishing off the top surface.”
The other type of concrete that should be addressed is “high-flow” concrete—this is not quite SCC but is concrete that still flows easily (slump flows between about 14 and 18 inches or even up to 20 inches). This class of concrete is lower priced than 5CC and more robust but still has most of the advantages (rapid placement, fewer workers needed, good finished surfaces). This is a very practical material but it does require some mechanical consolidation (vibration). “If there is access for vibrators then don’t use SCC, but consider “high-flow” concrete,” said Jack Gibbons, technical director for the Concrete Reinforcing Steel Institute, Schaumburg, Ill. “Trump Tower and the Aqua in Chicago are great examples of using 21st century methods without the expense and risk of SCC.”
Photobucket 
Proper consolidation is often a judgment call-experienced operators can tell 
if they are getting good consolidation by the sound of the vibrator

Vibration equipment

Photobucket

The critical questions for the vibrator operator  
 are how far apart to insert the vibrator and 
how deep to penetrate into the preceding lift.

The first decision to make in consolidating concrete is whether to use internal vibration or external vibrators mounted on the outside of the forms.
For this article, we will cover only internal vibration, because that is the most common technique used in the field. External or form vibration is nearly always used in precast plants and sometimes in field applications where the forms arc getting multiple uses and being moved as an assembly (gang forms) from place to place.
Internal vibration equipment is available from a variety of manufacturers although it all works in similar ways:
•Concrete vibrators develop vibration by spinning an eccentric weight within a housing (the vibrator head) typically at a very high speed. This action creates vibrations in the range of 10,000 to 17,000 vibrations per minute.
• Flexible shaft vibrators are the most common type used, where a flexible drive shaft in a housing spins the eccentric weight inside the vibrator head. The core of the flexible shaft is made from high-strength braided steel wire and the casing is steel reinforced rubber. Shafts come in various standard lengths up to about 20 feet long, although shafts can be coupled up to 65 feet.
• The shaft may be driven by an electric motor or by a gasoline or diesel engine. Some power units turn at speeds high enough to develop the required and others must be geared
to achieve the needed speed. There are also pneumatic motors available to drive flexible shaft vibrators.
• Some manufacturers have developed quick connect systems between power units and shafts and between shafts and heads.
• Gas power units often come rigged to he carried like a backpack, freeing a worker from having to hold the power unit in one hand.
• Electric motor-in-head vibrators are also available; in these vibrators a small three-phase induction motor is powered by a heavy electrical cable that also serves as the vibrator handle.
• Pneumatic vibrators are used when compressed air is readily available and when vibrators must run for extended continuous periods, such as in mass concrete. The pneumatic motor is in the vibrator head and tends not to heat up like other vibrator s.
• Radius of influence (or radius of action) is the critical parameter in vibrator selection—this is the distance from the center of the vibrator to the farthest distance where complete consolidation will occur in the concrete. Vibrator heads are rated for radius of influence, although this distance varies with the concrete slump— with high slump mixes it can he double the listed value.
• Vibrator heads come in various shapes, diameters, and lengths.
There is no definitive evidence that one shape works better than another, although some dimpled geometries seem to be more efficient. The head size should be matched to the desired radius of influence and the power unit should he matched to the head size.
• With large headed vibrators and larger power units (as big as about 5.5 hp), the radius of action can he as high as 18 inches. Vibrator heads come with regular steel heads or with urethane (rubber) heads. Rubber heads are required with epoxy- coated rebar, where a standard steel head can chip the epoxy and allow corrosion of the steel. Most DOTs require non-metal vibrator heads with epoxy-coated bars.
• Rubber tips are available for steel heads to protect form panels from damage by vibrator tips.
• Undersized extension cords for electric drive motors can lower a vibrator’s performance and even burn out the motor. For example, a 15 0-ft extension cord powering a 2.25 hp motor should have 8 gage wires.
• Manufacturers have developed rebar vibrators that have proven to effectively consolidate concrete and also grout in reinforced masonry. A study at the University of Tennessee on reinforced masonry showed that rebar vibrators were “an acceptable alternative to conventional pencil vibrators.”

Tips and Techniques for proper vibration

Concrete Placed Into forms always includes some entrapped air (as much as 30% of the volume of the concrete), especially stiffer mixes, and this air can get stuck in the concrete along form surface, near the corners, and beneath reinforcing steel. Consolidation is getting as much of this air as possible out of the concrete. What we arc trying to remove is entrapped air not entrained air. Entrained air is there for a purpose—to prevent freeze-thaw damage. Entrapped air serves no beneficial purpose, rather it results in honeycombed surfaces, poor bond development between the concrete and reinforcement, lower strength in the concrete, and higher concrete permeability that can result in rebar corrosion. Good consolidation overcomes these problems and also eliminates rock pockets and lift lines resulting in beautiful smooth concrete surfaces.
The science of how a material like concrete flows is called rheology. Traditionally, workability has been defined by slump, hut mixes with the same slump can behave very differently (have different rheology), especially when the mix includes water-reducing admixtures. The theological properties of fresh concrete include its yield stress and viscosity, which together define workability and how easy a concrete will consolidate. Rheology is something every concrete person should understand.
Stiff, low-water concrete mixes are intended to achieve high strength and low permeability, but without good consolidation these objectives can’t be achieved. Added water will allow easier consolidation but lower the strength of the mix. Fluidity can be achieved with admixtures, most notably superplasticizers (or high-range water reducing adrnixtures), but these admixtures are expensive and not always necessary with good consolidation technique.
With more fluid concrete and when placing flatwork, manually pushing and tamping the concrete or banging on the outside of the forms can usually remove most of the entrapped air. Stiff, low water content mixes, though, require more effort. With most formed concrete, mechanical consolidation is the best way to improve the quality of the work. Consolidation isn’t difficult, but can be ineffective without the proper equipment and technique. Here are some tips to improve your concrete through consolidation. 

Photobucket

Fluidity can be achieved using superplasticizers, 
but they are expensive and not always necessary with good consolidation technique
 